CABLE STRUCTURE 1- CONDUCTOR : IEC 60228 class 2 or class 5 tinned or bare copper 2- INSULATION : IEC 60092-351 cross-liked polyethylene ... More
CABLE STRUCTURE
1- CONDUCTOR : IEC 60228 class 2 or class 5 tinned or bare copper
2- INSULATION : IEC 60092-351 cross-liked polyethylene (XLPE)
3- TWIST : Appropriate steps in layers
4- INNER SHEAT : PES tape or compound HFFR
5- SCREEN : Tinned copper or annealed copper wire braided screen (min. 90%0ff)
6- SHEATH : IEC 60092-359 HFFR compounnd
SHEATH COLOUR : RAL 9005 black or RAL 7001 gray
PRODUCTION AND TEST STANDARDS
CONSTRUCTION : IEC 60092/353
TESTS AND MATERIAL : IEC 60092/350-351-359
FLAME RETARDATION : IEC 60332/1, IEC 60332 / 3 Cat A
INSULATION RESISTANCE : 5000 MΩkm
TEST VOLTAGE : 3,5 kV. AC
OPERATING VOLTAGE : 0,6 kV./1 kV.
BENDING RADIUS : 8 x D
OPERATING TEMPERATURE : -40°C / +90°C
FLAME TEST : IEC 60332-1-2 IEC 60332-3-22 (CAT-A)
SMOKE DENSITY : IEC 61034-2
CORROSIVE GAS TEST : IEC 60754-2
HALOGEN TEST : IEC 60754-1
APLICATION: Power conjure and control cable, marine applications and ship building of any kind, shipyards, marinas and ports are used.
ENVIRONMENT: Moist, wet, dry areas, indoor and outdoor environments is available.Front deck is suitable for fixed wiring.
SAFETY: Due to its' halogen-free low smoke density and flame retardant features, it wan't create corrosive gases nor abstruct visibility and prevents the fire from spreading around.Thus it protects human life and equipment, during a fire.